{"id":6661,"date":"2021-06-11T09:36:29","date_gmt":"2021-06-11T08:36:29","guid":{"rendered":"https:\/\/www.solidapps.co.uk\/blog\/?p=6661"},"modified":"2021-06-11T09:36:29","modified_gmt":"2021-06-11T08:36:29","slug":"solidworks-support-monthly-news-june-2021","status":"publish","type":"post","link":"https:\/\/www.solidapps.co.uk\/blog\/2021\/06\/solidworks-support-monthly-news-june-2021\/","title":{"rendered":"SOLIDWORKS Support Monthly News \u2013 June 2021"},"content":{"rendered":"\n<p>Hello to all,<\/p>\n\n\n\n<p>Welcome to the new edition of the SOLIDWORKS Support Monthly News!&nbsp; This monthly news blog is co-authored by members of the SOLIDWORKS Technical Support teams worldwide.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Synchronizing a Patterned Component to a Seed in SOLIDWORKS 2021<\/strong><\/h2>\n\n\n\n<p><em>By Deepika Pujari<\/em><\/p>\n\n\n\n<p>In SOLIDWORKS 2020 and earlier versions, when patterning components in a SOLIDWORKS assembly, there have been options to vary the configuration of one or more patterned component instances, so that a user can have a different configuration than the pattern seed.&nbsp; However, sometimes we need to ensure that all instances use the same configuration as the seed.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-79.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-79.png\" alt=\"\" class=\"wp-image-28650\"\/><\/a><\/figure>\n\n\n\n<p>Starting with SOLIDWORKS 2021, you can turn on Synchronize seeded patterned component configurations to synchronize the configuration of all patterned instances with the seed component configuration in the assembly. For every type of Component Pattern, and for Mirror Components, we can see a new checkbox in the Options section.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-65.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-65.png\" alt=\"\" class=\"wp-image-28651\"\/><\/a><\/figure>\n\n\n\n<p>By default, the option checkbox is UNCHECKED\/OFF.<\/p>\n\n\n\n<p>In the case of an existing component pattern, which has instances where the configuration already differs from the seed configuration, the user gets warned that the configuration of the patterned instances will be set back to match the seed.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-65.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-65.png\" alt=\"\" class=\"wp-image-28652\"\/><\/a><\/figure>\n\n\n\n<p>Now the results in the assembly,<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/4-58.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/4-58.png\" alt=\"\" class=\"wp-image-28653\"\/><\/a><\/figure>\n\n\n\n<p>With this option CHECKED\/ON, a user cannot change the configuration of the patterned\/mirrored instances via<\/p>\n\n\n\n<p>a) Component Properties: The Referenced Configuration section is disabled (greyed out).<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/5-53.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/5-53.png\" alt=\"\" class=\"wp-image-28654\"\/><\/a><\/figure>\n\n\n\n<p>b) Configure component command: The Configuration section is disabled (greyed out).<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/6-46.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/6-46.png\" alt=\"\" class=\"wp-image-28655\"\/><\/a><\/figure>\n\n\n\n<p>c) Context Menu: Configuration dropdown list is not available.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/7-37.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/7-37.png\" alt=\"\" class=\"wp-image-28656\"\/><\/a><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Controlling the display of hidden edges of Geometry with Composer 2021<\/strong><\/h2>\n\n\n\n<p><em>By Richie More<\/em><\/p>\n\n\n\n<p>SOLIDWORKS Composer helps Documentation Team get up to speed with creation of Documentation content with use of CAD files. Most of the process involves selection of Components or mere highlighting them.<\/p>\n\n\n\n<p>What\u2019s New in SOLIDWORKS Composer 2021 is the ability to control the intensity of the&nbsp;<strong>SELECTION&nbsp;<\/strong>color and the&nbsp;<strong>HIGHLIGHT<\/strong>&nbsp;color.<\/p>\n\n\n\n<p><strong>Procedure to control Edge display.<\/strong><\/p>\n\n\n\n<p><strong>Step 1<\/strong>\u2013 Open any project in Composer 2021<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-14.jpg\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-14-615x574.jpg\" alt=\"\" class=\"wp-image-28659\"\/><\/a><\/figure>\n\n\n\n<p><strong>Step 2-&nbsp;<\/strong>Navigate File &gt; Properties &gt; Document Properties &gt; Selection<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-14.jpg\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-14.jpg\" alt=\"\" class=\"wp-image-28660\"\/><\/a><\/figure>\n\n\n\n<p><strong>Step 3-&nbsp;<\/strong>Modify the intensity for&nbsp;<strong>SELECTION<\/strong>&nbsp;and&nbsp;<strong>HIGHLIGHT.&nbsp;<\/strong>Hit&nbsp;<strong>Apply<\/strong>&nbsp;and&nbsp;<strong>OK<\/strong>. This will modify how the&nbsp;<strong>SELECTION<\/strong>&nbsp;and&nbsp;<strong>HIGHLIGHT<\/strong>&nbsp;actors are displayed in the Composer viewport.<\/p>\n\n\n\n<p>For Comparison :<\/p>\n\n\n\n<p>Composer 2020 :<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-14.jpg\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-14.jpg\" alt=\"\" class=\"wp-image-28661\"\/><\/a><\/figure>\n\n\n\n<p>Composer 2021:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/4-10.jpg\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/4-10.jpg\" alt=\"\" class=\"wp-image-28662\"\/><\/a><\/figure>\n\n\n\n<h1 class=\"wp-block-heading\"><strong>SOLIDWORKS PDM 2021 uses Bill of Materials options specified in SOLIDWORKS.&nbsp;<\/strong><\/h1>\n\n\n\n<p><em>By Rohit Magar<\/em><\/p>\n\n\n\n<p>SOLIDWORKS PDM 2021 now supports the \u201cShow\u201d, \u201cHide\u201d and&nbsp;<strong>\u201cPromote\u201d<\/strong>&nbsp;Bill of Material options used with SOLIDWORKS. When you use the configuration of the subassembly in main assembly, these settings are available under Bill of Material Options in Configuration Properties.&nbsp; The settings control if and how the child components appear in a bill of materials of the top-level assembly.<\/p>\n\n\n\n<p>These Bill of Material options specified in the Configuration properties PropertyManager in SOLIDWORKS CAD, will now be used in the Computed BOMs of SOLIDWORKS PDM.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-80.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/1-80-238x615.png\" alt=\"\" class=\"wp-image-28664\"\/><\/a><\/figure>\n\n\n\n<p><strong>SOLIDWORKS Bill of Material Options<\/strong><\/p>\n\n\n\n<p>Let us see what each of the three BOM options provide:<\/p>\n\n\n\n<p><strong><em>Bill of Materials Options:<\/em><\/strong><strong>&nbsp;Show<\/strong><\/p>\n\n\n\n<p>Selection of this option will shows the child components in the BOM if dictated by BOM Type in the Bill of Materials PropertyManager. Child components do not show in a Top-level only BOM.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-66.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/2-66.png\" alt=\"\" class=\"wp-image-28665\"\/><\/a><\/figure>\n\n\n\n<p>Notice in the above image, it shows the subassembly and all the child components within it when \u201cShow\u201d option is selected.<\/p>\n\n\n\n<p><strong><em>Bill of Materials Options:<\/em><\/strong><strong>&nbsp;Hide<\/strong><\/p>\n\n\n\n<p>Hides the child components in the BOM, the subassembly appears as a single item in the BOM.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-66.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/3-66.png\" alt=\"\" class=\"wp-image-28666\"\/><\/a><\/figure>\n\n\n\n<p>Notice in the above image, it show the subassembly but hide the child components within it.<\/p>\n\n\n\n<p><strong>Bill of Materials Options: Promote<\/strong><\/p>\n\n\n\n<p>For instance, when \u201cpromote\u201d is used, only the subassembly child\u2019s components are visible at the computed BOM level. Dissolves the subassembly in the BOM and shows the child components, even if the BOM Type does not show them.<a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/4-59.png\"><\/a><\/p>\n\n\n\n<p>Notice in the above image, this option dissolve the subassembly but shows the child components.<\/p>\n\n\n\n<p><strong>Link to Parent Configuration&nbsp;<\/strong>option for derived configuration:<\/p>\n\n\n\n<p>Additionally, there is an option for the Part number displayed when used in a bill of materials.&nbsp;&nbsp;<strong>Link to Parent Configuration<\/strong>&nbsp;option will set the setting same as the parent configuration name. This option is only available for derived configurations.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/5-54.png\"><img decoding=\"async\" src=\"http:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/5-54.png\" alt=\"\" class=\"wp-image-28668\"\/><\/a><\/figure>\n\n\n\n<h1 class=\"wp-block-heading\"><strong>Noteworthy Solutions from the SOLIDWORKS Knowledge Base<\/strong><\/h1>\n\n\n\n<p><strong>&nbsp;When I use SOLIDWORKS\u00ae default file properties such as \u2018SW-Mass\u2019 and \u2018SW-Density\u2019 to define any dimension when using equations, why do I receive the \u2018\u2026potential circular reference\u2026\u2019 warning?<\/strong><\/p>\n\n\n\n<p>This is intentional behaviour. SOLIDWORKS\u00ae default file properties (like \u2018SW-Mass\u2019 and \u2018SW-Volume\u2019) are driven properties. These properties update after solving the equations and rebuilding the part. To get more information, see Solution Id:\u00a0<a rel=\"noreferrer noopener\" href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-ATQGVF4\" target=\"_blank\">S-079096<\/a><\/p>\n\n\n\n<p><strong>\u00a0In the SOLIDWORKS\u00ae software, after saving an imported assembly with 3D Interconnect, once dissolved, how do I avoid seeing the message \u2018More than one components are saved at the same location\u2019?<br><\/strong>This behavior probably occurs because virtual components with the same name exist in different subassemblies. When the link with the 3D Interconnect feature is broken, SOLIDWORKS\u00ae does not permit the saving. To get more information, see Solution Id:\u00a0<a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-ATT8LB4\" target=\"_blank\" rel=\"noreferrer noopener\">S-079097<\/a><\/p>\n\n\n\n<p><strong>\u00a0When I use the SOLIDWORKS\u00ae PDM 2020 or later software, why does the Windows\u00ae Application event log on the SQL Server\u00ae computer show many \u2018Process ID NN was killed by hostname\u2019 messages?<\/strong><br>The SOLIDWORKS\u00ae PDM 2020 software introduces asynchronous loading of data when you browse between folders in the file vault view. This also happens when you view the \u2018Contains\u2019, \u2019Where Used\u2019 and \u2018BOM\u2019 preview tabs, and when you load files in SOLIDWORKS\u00ae while the SOLIDWORKS PDM add-in is active.. To get more information, see Solution Id:\u00a0<a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-ATA2GEF\" target=\"_blank\" rel=\"noreferrer noopener\">S-079067<\/a><\/p>\n\n\n\n<p><strong>Is there an example showing how SOLIDWORKS\u00ae Flow Simulation estimates the operating point of an axial fan from its curve?<\/strong><\/p>\n\n\n\n<p>Yes. See the example file and image in the attachments of Solution Id:\u00a0<a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-ATXQT8N\" target=\"_blank\" rel=\"noreferrer noopener\">S-079106<\/a><\/p>\n\n\n\n<p>That\u2019s it for this month. Thanks for reading this edition of SOLIDWORKS Support News.<\/p>\n\n\n\n<p>Originally posted in the <a href=\"https:\/\/blogs.solidworks.com\/tech\/2021\/06\/solidworks-support-monthly-news-june-2021.html\" data-type=\"URL\" data-id=\"https:\/\/blogs.solidworks.com\/tech\/2021\/06\/solidworks-support-monthly-news-june-2021.html\" target=\"_blank\" rel=\"noreferrer noopener\">SOLIDWORKS Tech Blog<\/a>. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hello to all, Welcome to the new edition of the SOLIDWORKS Support Monthly News!&nbsp; This monthly news blog is co-authored by members of the SOLIDWORKS Technical Support teams worldwide. Synchronizing&hellip; <\/p>\n","protected":false},"author":1,"featured_media":6662,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5,9,7],"tags":[101,25,57,62,26],"class_list":["post-6661","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solidworks","category-solidworks-composer1","category-solidworks-epdm","tag-news","tag-solidworks-2","tag-solidworks-composer","tag-solidworks-enterprise-pdm","tag-support"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/comments?post=6661"}],"version-history":[{"count":1,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6661\/revisions"}],"predecessor-version":[{"id":6663,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6661\/revisions\/6663"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/media\/6662"}],"wp:attachment":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/media?parent=6661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/categories?post=6661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/tags?post=6661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}