{"id":6230,"date":"2019-12-13T11:10:34","date_gmt":"2019-12-13T11:10:34","guid":{"rendered":"https:\/\/www.solidapps.co.uk\/blog\/?p=6230"},"modified":"2019-12-13T11:10:34","modified_gmt":"2019-12-13T11:10:34","slug":"solidworks-support-monthly-news-december-2019","status":"publish","type":"post","link":"https:\/\/www.solidapps.co.uk\/blog\/2019\/12\/solidworks-support-monthly-news-december-2019\/","title":{"rendered":"SOLIDWORKS Support Monthly News \u2013 December 2019"},"content":{"rendered":"<p>Hello to all,<\/p>\n<p>Welcome to the new edition of the SOLIDWORKS Support Monthly News!\u00a0 This monthly news blog is co-authored by members of the SOLIDWORKS Technical Support teams worldwide.<\/p>\n<p>&nbsp;<\/p>\n<h2>How to display the SOLIDWORKS PDM workflow state in a SOLIDWORKS Manage report<\/h2>\n<p><em>By Kevin Crawford<\/em><\/p>\n<p>There may be times where you will want a Bill of Materials report in Manage to display the SOLIDWORKS PDM workflow state.\u00a0 To do this requires some additional setup work.<\/p>\n<p>To display the PDM workflow state in a Manage report you first need to create a PDM variable and add it to the data card.\u00a0 To avoid any manual changes, the text box should be read-only and have a default value of the first workflow state for newly added files.\u00a0 In the below image, a variable called \u201cPDM Status\u201d was created and connected it to a text box on the data card.\u00a0 The text box is read-only and has a default value of the first workflow state, \u201cDevelopment\u201d.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-25559 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card-300x198.jpg\" sizes=\"auto, (max-width: 660px) 100vw, 660px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card-300x198.jpg 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card-615x407.jpg 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card-768x508.jpg 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card-728x481.jpg 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Model-Card.jpg 945w\" alt=\"\" width=\"660\" height=\"436\" \/><\/p>\n<p>Edit the workflow and modify the transitions to include an action to set the \u201cPDM Status\u201d variable to the destination state name.\u00a0 Adding the action to all transitions will update the variable anytime the file changes states.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-25561 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition-300x206.jpg\" sizes=\"auto, (max-width: 435px) 100vw, 435px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition-300x206.jpg 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition-615x423.jpg 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition-768x528.jpg 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition-728x500.jpg 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/transition.jpg 828w\" alt=\"\" width=\"435\" height=\"299\" \/><\/p>\n<p>In Manage, edit the PDM Object (Options &gt; Administration Options &gt; Structures &gt; Documents &amp; Records, and edit the PDM vault).\u00a0 On the Connection page of the wizard, select \u201cEnable Synchronization and get all PDM objects\u201d and run the synchronization.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-25565 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1-300x213.jpg\" sizes=\"auto, (max-width: 632px) 100vw, 632px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1-300x213.jpg 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1-615x437.jpg 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1-768x546.jpg 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1-728x518.jpg 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Configuration-1.jpg 872w\" alt=\"\" width=\"632\" height=\"449\" \/><\/p>\n<p>The \u201cPDM Status\u201d variable will now be seen on the Fields page.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-25564 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config-300x212.jpg\" sizes=\"auto, (max-width: 553px) 100vw, 553px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config-300x212.jpg 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config-615x435.jpg 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config-768x544.jpg 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config-728x515.jpg 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Multi-Config.jpg 873w\" alt=\"\" width=\"553\" height=\"391\" \/><\/p>\n<p>On the Bill of Materials page, edit the BOM and create a new field.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-25566 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config-300x235.jpg\" sizes=\"auto, (max-width: 606px) 100vw, 606px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config-300x235.jpg 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config-615x482.jpg 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config-768x602.jpg 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config-728x571.jpg 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-Config.jpg 872w\" alt=\"\" width=\"606\" height=\"475\" \/><\/p>\n<p>The new field will be a Mapped Field.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25372 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field-300x210.png\" sizes=\"auto, (max-width: 689px) 100vw, 689px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field-300x210.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field-615x431.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field-768x538.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field-728x510.png 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-configuration-mapped-field.png 894w\" alt=\"\" width=\"689\" height=\"482\" \/><\/p>\n<p>Under the Options tab, you\u2019ll need to map the field to the field of the file.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25373 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties-300x210.png\" sizes=\"auto, (max-width: 724px) 100vw, 724px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties-300x210.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties-615x431.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties-768x538.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties-728x510.png 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/field-properties.png 894w\" alt=\"\" width=\"724\" height=\"507\" \/><\/p>\n<p>On the Views tab, edit the view and set the PDM Status field to visible.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25374 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-properties-1-300x204.png\" sizes=\"auto, (max-width: 735px) 100vw, 735px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-properties-1-300x204.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/BOM-properties-1-615x419.png 615w\" alt=\"\" width=\"735\" height=\"499\" \/><\/p>\n<p>On the Reports page, edit the Report<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25375 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page-300x213.png\" sizes=\"auto, (max-width: 777px) 100vw, 777px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page-300x213.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page-615x436.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page-768x545.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page-728x517.png 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/report-page.png 995w\" alt=\"\" width=\"777\" height=\"552\" \/><\/p>\n<p>Add the PDM Status column to the report.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25376 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-report-300x234.png\" sizes=\"auto, (max-width: 917px) 100vw, 917px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-report-300x234.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-report-615x481.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-report-768x600.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/manage-report-728x569.png 728w\" alt=\"\" width=\"917\" height=\"715\" \/><\/p>\n<p>Now, after files are transitioned through the PDM workflow, the Manage report will now contain the PDM Status.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-25377 aligncenter colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report-300x285.png\" sizes=\"auto, (max-width: 544px) 100vw, 544px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report-300x285.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report-615x583.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report-768x728.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report-728x690.png 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/final-report.png 795w\" alt=\"\" width=\"544\" height=\"517\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>About DWG Files in SOLIDWORKS PDM<\/h2>\n<p><em>By James Falconer<\/em><\/p>\n<p>DWG files are one of the most popular filetypes that SOLIDWORKS PDM manages within a vault. Did you know that both SOLIDWORKS PDM Standard and PDM Pro give you the ability to manage these files? And no add-ins are needed when you are using Windows Explorer to manage them!<\/p>\n<p><strong>How is SOLIDWORKS PDM able to manage DWG files?<\/strong><\/p>\n<p>We use the ODA API to read DWG files. The ODA (OpenDWG Alliance) is a group of over 1,000 companies that support the development of tools that allow our software to read and write to DWG files.<\/p>\n<p><strong>Are there different DWG file formats?<\/strong><\/p>\n<p>About once every 3 years there is a new major release of the DWG format. You can tell which version file format you have by simply opening the DWG file in a text reader, such as Notepad (for small files), or Notepad++ (for larger files).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-25539 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Edit-with-Notepad-300x143.png\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Edit-with-Notepad-300x143.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Edit-with-Notepad.png 369w\" alt=\"\" width=\"300\" height=\"143\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-25540 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad-300x149.png\" sizes=\"auto, (max-width: 725px) 100vw, 725px\" srcset=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad-300x149.png 300w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad-615x305.png 615w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad-768x381.png 768w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad-728x361.png 728w, https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/notepad.png 889w\" alt=\"\" width=\"725\" height=\"360\" \/><\/p>\n<p>The first 6 characters will tell you which DWG file format you are viewing. In the image above we can tell it is a DWG file format from 2018 \u2013 2020 because the first 6 characters are <strong>AC1032<\/strong>.<br \/>\nFor reference, here are the DWG file versions for the previous 12 years;<\/p>\n<p><strong>AutoCAD<\/strong> 2018 \u2013 <strong>AutoCAD<\/strong> 2020: <strong>AC1032<\/strong><br \/>\n<strong>AutoCAD<\/strong> 2013 \u2013 <strong>AutoCAD<\/strong> 2017: <strong>AC1027<\/strong><br \/>\n<strong>AutoCAD<\/strong> 2010 \u2013 <strong>AutoCAD<\/strong> 2012: <strong>AC1024<\/strong><br \/>\n<strong>AutoCAD<\/strong> 2007 \u2013 <strong>AutoCAD<\/strong> 2009: <strong>AC1021<\/strong><\/p>\n<p><strong>Does SOLIDWORKS PDM Standard support DWG files?<\/strong><\/p>\n<p>Yes! SOLIDWORKS PDM Standard allows you the ability to manage DWG files in the Windows Explorer Vault View. You are able to manage DWG files just like many other filetypes; Push them through a workflow, check them out, view the data card, etc.<\/p>\n<p><strong>Do I need the AutoCAD, or DraftSight add-in to manage DWG files inside a vault?<\/strong><\/p>\n<p>No! You only need to own a license of SOLIDWORKS PDM Standard or SOLIDWORKS PDM Pro to manage DWG files from within the vault. The ODI integration is part of both SOLIDWORKS PDM Standard and SOLIDWORKS PDM Pro.<\/p>\n<p>&nbsp;<\/p>\n<h2>Noteworthy Solutions from the SOLIDWORKS Knowledge Base<\/h2>\n<p>&nbsp;<\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-408 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Screen-capture3.png\" alt=\"icon - SW\" width=\"16\" height=\"16\" \/> Technical Alert: Important Information Regarding SOLIDWORKS 2020 SP0<\/b><br \/>\nFor more information, check out Solution Id: <a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-A3KZBE8\" target=\"_blank\" rel=\"noopener noreferrer\">S-077218<\/a>.<\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-7480 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/SOLIDWORKS-Electrical-Icon.png\" alt=\"\" width=\"16\" height=\"16\" \/> If SOLIDWORKS\u00ae Electrical crashes on startup how do I fix a problem where the event log shows that the SOLIDWORKSElectrical.exe error model is ole32.dll?<\/b><br \/>\nFor more information on this, see Solution Id: <a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-9ZPGY8G\" target=\"_blank\" rel=\"noopener noreferrer\">S-076997<\/a>.<\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-405 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Screen-capture1.png\" alt=\"Icon - EPDM\" width=\"16\" height=\"16\" \/> General Hotfix for SOLIDWORKS\u00ae PDM 2018 and 2019 \u2013 File Version Upgrade Tool (SPR#1151052)<\/b><br \/>\nFor more information, see Solution Id: <a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-A1SY8A2\" target=\"_blank\" rel=\"noopener noreferrer\">S-077143<\/a>.<\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-410 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Screen-capture4.png\" alt=\"\" width=\"16\" height=\"16\" \/> For a Nonlinear study that uses viscoelastic material under constant loading, why do the stress results show no sign of stress relaxation no matter how much I increase the total solution time?<br \/>\n<\/b>For more information on this, check out Solution Id: <a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-9ZNT1L2\" target=\"_blank\" rel=\"noopener noreferrer\">S-076990<\/a>.<\/p>\n<p><b><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-639 colorbox-25362\" src=\"https:\/\/blogs.solidworks.com\/tech\/wp-content\/uploads\/sites\/4\/Flow-Simulation-icon.png\" alt=\"\" width=\"16\" height=\"16\" \/> In SOLIDWORKS\u00ae Flow Simulation, is it possible to simulate an adiabatic compression like in a combustion engine?<\/b><br \/>\nFor more information, check out Solution Id: <a href=\"https:\/\/customerportal.solidworks.com\/siebel\/app\/customerportal\/enu?SWECmd=GotoView&amp;SWEView=SW+OUI+KBase+Solution+View+(eService)&amp;SWERF=1&amp;SWEBU=1&amp;SWEApplet0=SW+OUI+KBase+Solution+Form+Applet+(eService)&amp;SWERowId0=1-A014M0C\" target=\"_blank\" rel=\"noopener noreferrer\">S-077066<\/a>.<\/p>\n<hr \/>\n<p>That\u2019s it for this month. Thanks for reading this edition of SOLIDWORKS Support News.<\/p>\n<p>&nbsp;<\/p>\n<p>Originally posted in the <a href=\"https:\/\/blogs.solidworks.com\/tech\/2019\/12\/solidworks-support-monthly-news-december-2019.html\" target=\"_blank\" rel=\"noopener noreferrer\">SOLIDWORKS Tech Blog<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Hello to all, Welcome to the new edition of the SOLIDWORKS Support Monthly News!\u00a0 This monthly news blog is co-authored by members of the SOLIDWORKS Technical Support teams worldwide. &nbsp;&hellip; <\/p>\n","protected":false},"author":1,"featured_media":6231,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5,158,7],"tags":[25,159,62],"class_list":["post-6230","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solidworks","category-solidworks-manage","category-solidworks-epdm","tag-solidworks-2","tag-solidworks-manage","tag-solidworks-enterprise-pdm"],"post_mailing_queue_ids":[],"_links":{"self":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6230","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/comments?post=6230"}],"version-history":[{"count":1,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6230\/revisions"}],"predecessor-version":[{"id":6232,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/posts\/6230\/revisions\/6232"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/media\/6231"}],"wp:attachment":[{"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/media?parent=6230"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/categories?post=6230"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.solidapps.co.uk\/blog\/wp-json\/wp\/v2\/tags?post=6230"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}